Industrial Desert Cooler 30 HP |
|
General
Specifications |
 |
Unit Dry Weight |
: 1,575 kg. |
 |
 |
Unit Wet Weight |
: 3,590 kg. |
 |
Unit Body |
: 3 mm.
Galvanize Steel |
 |
Unit Paint Type |
: Epoxy Paint |
| |
|
|
Blower
Specifications |
 |
Nominal Air
Capacity |
: 95,000 CFM |
 |
 |
Rated Air
Capacity |
: 70,000 - 90,000 CFM |
 |
Rated Air
Velocity |
: 7,500 - 10,500 f/min |
 |
Fins Thickness |
: 2 mm Galvanize Steel |
 |
Fan Rings Thickness |
: 4 mm Galvanize Steel |
 |
Fan Housing Thickness |
: 1.2 mm Galvanize Steel |
 |
All
Pressures ( Static, : Pst 1 / Pst 2 = ( n1 / n2 )2 =
(V1 / V2)2 dynamic and
Total) |
 |
change proportionately to the square of the speed |
|
| |
|
|
| Pst [ in WG.] |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
| CFM |
91,750 |
87,700 |
83,131 |
76,595 |
71,550 |
65,130 |
58,510 |
|
|
|
|
Fan Motor |
 |
Power |
: 22 kw /30 hp |
 |
 |
 |
Voltage |
: 220-380-460 v/3pH/60Hz |
 |
Speed |
: 1,770 r/min |
 |
Protection |
: IP 55 CI.F. |
 |
Motor Amps |
: 40-39 Amps |
|
|
|
|
KSB |
LorySomer |
|
Fan Bearing |
 |
brand Name |
: SKF or equivalent |
 |
 |
Manufacture |
: Japan |
 |
Case |
: Waterproof |
|
|
|
|
|
Pump
Specificationa |
 |
Power |
: 0.75 kw / 1 hp |

GRUNDEFOS |
EBARA
 |
 |
Voltage |
: 220/230 v / 1pH/60Hz |
 |
Protection |
: IP 55 CI.F. |
 |
Capacity |
50 / 150 /l/min |
 |
Head |
29 - 16 m |
 |
Pump Amps |
4.1 Amps |
|
|
|
|
|
|
|
|
|
NAUTI |
|
Control
Panel |
 |
Industrial Control Panel with
all Preservation parts and indicators |
|
|
 |
 |
|
|
|
|
|
|
Electrical
Diagram |
 |
|
Direct
Evaporative Cooling |
 |
Direct evaporative cooling
exchanges sensible heat for latent heat, |
 |
|
|
and follows upward along a
constant wet-bulb temperature line one the Psychometric
Chart. The result is a dry-bulb temperature of the leaving
air (B) approaching the wet-bulb temperature of the entering
air (A). |
|
|
Whenever water is evaporated,
heat is absorbed. This basic principle underlines the design
of the MEGA COOL direct
evaporative cooling. |
|
|
|
|
|
Evaporative
Cooling Media |
 |
Media |
: Carton Cellulose material |
|
 |
Design |
: Cross fluted continuallt
directs |
|
|
|
|
water to the
Air-Entering side |
|
 |
Water Direction |
: From Top to Bottom |
|
|
|
|
|
|
|
Cooling Pads
Frame |
 |
Media |
: Stainless Steel or Galvanize
Steel |
 |
 |
Design |
: To keep the Cellulose in good
Condition |
|
|
|
|
|
|
|
|
|
|
|
|
|
Water
Distribution |
 |
Water distribution was designed
equally to all cooling pads |
 |
|
|
through special 8mm diameter
Holes, fixed on plastic pipes ( to prevent scaling inside
holed ) and distributed as three holed for each cooling pad |
 |
Water Tray is designed in
unique way to guarantee continuous water flow from the sides |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Water
Drizzle Trap |
 |
Contact our Technical
Department by clicking here |
 |
|
Nozzles
Partitions |
 |
Contact our Technical
Department by clicking here |
 |
|
Unit
Dimentions |
 |
 |
 |
|
Unit Roof
Insulation |
 |
Brand Name |
: ARNON |
|
 |
Media |
: PE-Foam |
|
 |
Thickness |
: 15 mm |
|
 |
Thermal conductivity |
: 0.036 W / M.ْC |
|
 |
Thermal Resistance |
: 0.41 M2 ْC/W |
|
|
Installation
and Operational Requirements |
 |
Outdoor Humidity |
: Not More than 15% |
 |
Water Supply |
: Treated Water |
 |
Unit Boundary Clearance |
: Not less than 150 cm from
each suction side |
 |
Cellulose Cleaning |
: Weekly by pressure water |
 |
Water Tank Change |
: Twice a week |
 |
Unit Inner Painting |
: Yearly |
 |
Bearing Lubricated |
: Every two weeks |
 |
Motor Drain |
: (LeroySomer Motor Only) in
the beginning of season |
 |
Important Notes |
: |
|
|
|
(1) to improve efficiency, air
must be discharged (i.e open windows / doors / louvers) |
|
|
|
(2) to increase cooling rate,
we recommend installation of wall mounted fans, which will
increase air speed and reduce humidity |
|
|
|
|
|